REMOVE AND INSTALL INSTRUMENT PANEL ASSEMBLY
DISASSEMBLE AND ASSEMBLE INSTRUMENT PANEL ASSEMBLY

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  847    848    849    850    851  852  853    854    855    856    857  
img
TM 5-3805-280-24-2
Compressor
22
1--Panel Cover
10--Miniature Incadescent
19--Nut (6 used)
29--Push Button Spst
29
2--Diagnostic Module
Indicator (3 used)
20--Spacer (2 used)
Switch (2 used)
3--Toggle DPDT Switch (3
11--Cap Screw (6 used)
21--Cap Screw (2 used)
30--Cap Screw (2 used)
used)
12--Nut (6 used)
22--Nut (2 used)
31--Nut (2 used)
4--Cap Screw (4 used)
13--Incandescent Bulb (3
23--Strip Section Terminal
32--Heater Decal
5--Instrument Panel
used)
(16 used)
6--Control Panel Decal
14--Rivet (4 used)
24--Strip End Section
7--Restriction Indicator
15--Discharge Pressure
Terminal
Flange (2 used)
Gauge
25--Relay (2 used)
8--Street Elbow (2 used)
16--Hourmeter
26--Mag Switch Relay
9--Restriction Indicator (2
17--Lens
27--Cap Screw (2 used)
used)
18--Cap Screw (6 used)
28--Nut (2 used)
5. Repair and replace parts as necessary.
1. Remove cap screws (4), panel cover (1).
6. Install instrument panel (5), spacers (20), cap
2. Label all hoses and electrical connections.
screws (18) and nuts (19).
3. Disconnect all hoses and electrical connections.
7. Connect all hoses and electrical connections.
4. Remove cap screws (18), nuts (19), spacers (20)
8. Install panel cover (1) and cap screws (4).
and instrument panel (5).