TM 5-3805-280-24-2
22
DISASSEMBLE AND ASSEMBLE
30
INSTRUMENT PANEL ASSEMBLY
1. Remove parts (21--24).
2. Remove cap screws (27), nuts (28) and mag switch
3. Remove push button spst switches (29).
4. Remove retaining nut on front of DPDT switches (3) and
remove toggle DPDT switches (3).
5. Remove cap screws (11), nuts (12) and relay (25).
6. Remove rivets (14) and diagnostic module (2).
7. Remove cap screws (30), nuts (31), and restriction
indicator flanges (7), street elbows (8) and restriction
indicators (9).
8. Remove retaining nut and washer from back of
miniature incandescent indicator (10).
9. Remove parts (10, 13, 17 and 32).
10. Remove retaining nuts from back of discharge
pressure gauges (15) and hourmeter (16).
11. Remove discharge pressure gauges (15) and remove
hourmeter (16).
12. Remove control panel decal (6).
13. Repair or replace parts as necessary.
14. Install control panel decal (6).
15. Install discharge pressure gauges (15) and install
hourmeter (16).
16. Install retaining nuts to back of discharge pressure
gauges (15) and hourmeter (16).
17. Install decal (32) and retaining nut and washer to
back of miniature incadescent indicator (10).
18. Install parts (13 and 17).
Continue on nex page
d
t
CED,OUOE039,16 1915APR991/2
20-26