TM 5-3805-280-24-2
Hydraulic System
Propel Flow Control Valve and Orifice Fitting--Specification
20. System relief valve isolation check valve
poppet (22A and 22C): Tighten cap screws.
Torque....................................................................... 76 Nm (56 lb-ft)
System Relief Valve Isolation Check Valve Cover-to-Control
23. Fitting with orifice, O-ring and filter (25) for
Valve Housing Cap Screw--Specification
front and rear pump control valves: Tighten
Torque....................................................................... 61 Nm (45 lb-ft)
fitting.
21. Flow combiner valve check valve poppet (22B):
Front and Rear Pump Control Valve-to-Control Valve Housing
Fitting--Specification
Tighten cap screws (75).
Torque....................................................................... 34 Nm (25 lb-ft)
Flow Combiner Valve Check Valve-to-Control Valve Housing
Cap Screw--Specification
Torque....................................................................... 61 Nm (45 lb-ft)
22. Check valve and orifice (28) for propel flow
control valve: Tighten fitting (26).
TX,33,UU4003
1921SEP9817/17
33
3360
112