DISASSEMBLE AND ASSEMBLE CIRCUIT RELIEF AND ANTI-CAVITATION VALVE
REMOVE AND INSTALL HYDRAULIC OIL TANK

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  1005    1006    1007    1008    1009  1010  1011    1012    1013    1014    1015  
img
TM 5-3805-280-24-2
Hydraulic System
REMOVE AND INSTALL HYDRAULIC OIL
TANK
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
1. Loosen vent plug (A) to release air pressure in
hydraulic oil tank.
A--Vent Plug
2. Remove covers from the bottom and side of hydraulic
oil tank.
NOTE: It is not necessary to drain and remove the
hydraulic oil tank if only the return filter element is
being removed. (See procedures in this group.)
3. Drain hydraulic oil tank. Approximate oil capacity is 148
L (39 gal).
TX,33,UU3804
1921SEP981/6
Continued on next page
33
3360
116
21-148