REMOVE AND INSTALL SUCTION STRAINER - Continued
REMOVE AND INSTALL SWING MOTOR MAKE-UP OIL RESTRICTION VALVE

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  1019    1020    1021    1022    1023  1024  1025    1026    1027    1028    1029  
img
TM 5-3805-280-24-2
Hydraulic System
DISASSEMBLE AND ASSEMBLE HYDRAULIC
OIL TANK RELIEF VALVE AND BREATHER
FILTER CAP
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
1. Loosen vent plug (A) to release air pressure in
hydraulic tank.
A--Vent Plug
TX,33,UU3807
1921SEP981/2
2. Insert a 4 mm hex key wrench in base and turn to
release locking pin. Remove cap (A).
3. Remove cap screw (E). Remove parts (B--D).
Replace parts as necessary.
33
3360
130
A--Cap
B--Breather Filter
C--Seal
D--Relief Valve
E--Cap Screw (3 used)
TX,33,UU3807
1921SEP982/2
21-162