REMOVE AND INSTALL RETURN FILTER AND BYPASS VALVE - Continued
REMOVE AND INSTALL SUCTION STRAINER - Continued

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  1015    1016    1017    1018    1019  1020  1021    1022    1023    1024    1025  
img
TM 5-3805-280-24-2
Hydraulic System
REMOVE AND INSTALL SUCTION STRAINER
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
1. Loosen vent plug (B) to release air pressure in
hydraulic oil tank.
2. Drain hydraulic oil tank. Approximate oil capacity is 148
A--Filler Cap
L (39 gal).
B--Vent Plug
C--Cover
3. Remove the filler cap (A) and cover (C).
TX,33,GG2428 1913MAY981/4