REMOVE AND INSTALL RETURN FILTER AND BYPASS VALVE
REMOVE AND INSTALL SUCTION STRAINER

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  1014    1015    1016    1017    1018  1019  1020    1021    1022    1023    1024  
img
TM 5-3805-280-24-2
Hydraulic System
5. Install element (D) making sure it is pushed down on
its seat at bottom of case.
6. Install filter bypass valve (E), spring (C), O-ring (F),
cover (A) and cap screws (B).
Tighten cap screws.
Filter Bypass Valve-to-Cover Cap Screw--Specification
Torque ............................................................................. 49 Nm (36 lb-ft)
7. Add hydraulic oil as necessary. (See Hydraulic Oil in
Group 0004.)
IMPORTANT: Hydraulic pump will be damaged if not
filled with oil before starting. Procedure
must be performed to fill pump housing
whenever oil has been drained from the
pump or hydraulic oil tank.
8. If hydraulic oil tank was drained, do the Hydraulic
Pump Start-Up Procedure. (See procedure in this
group.)
A--Cover
B--Cap Screw
C--Spring
D--Element
E--Filter Bypass Valve
F--O-Ring
TX,33,UU3806
1921SEP983/3
33
3360
125
21-157