(2) Check grease:
a. Grease must be 13--25 mm (1/2--1in.) (B)
deep. Measured from the bottom of the
swing gear.
b. The grease must be free of contamination by
dirt and water. If the grease is contaminated,
remove grease and replace with clean grease
(see Fuels and Lubricants, Chapter 1).
NOTE: If water or mud is found in swing
gear area, refer to "Operating in Water and
Mud" in the Operating the Machine section.
(3) Add grease as required (approximately 0.113
kg [1/4 lb] every 90).
CAUTION: Excessive grease can damage the
swing gearbox seal.
(4) Remove excessive grease that extrudes over the
top of the swing drive pinion.
(5) Install access cover.