TM 5-3805-280-24-2
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD
ITEM
INTERVAL
ITEM TO BE INSPECTED
EQUIPMENT IS NOT
NO.
PROCEDURE: DO THE PMCS AND HAVE ITEM
READY/AVAILABLE
REPAIRED, FILLED, OR ADJUSTED AS NEEDED
IF:
Coolscan Plus
For a more thorough evaluation of coolant, perform
Coolscan Plus analysis.
(2) Add TY16004 John Deere Coolant Conditioner
or equivalent non-chromate conditioner/rust
inhibitor, following instructions on container.
COOLING SYSTEM SPECIFICATION
Cooling System Capacity
Approx. 22 L (6 gal)
26
Quarterly
Check Batteries
(Refer to Check Battery Electrolyte Level and Terminals
in the Electrical System Repair chapter.)
27
Semiannually
(1) Remove plug (A) to drain oil into a container.
Dispose of waste oil properly.
(2) Install plug.
(3) Remove filler cap (B) and add oil (see Fuels
SPECIFICATION
13 L (14 qt)
A-21