TM 5-3805-280-24-2
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD
ITEM
INTERVAL
ITEM TO BE INSPECTED
EQUIPMENT IS NOT
NO.
PROCEDURE: DO THE PMCS AND HAVE ITEM
READY/AVAILABLE
REPAIRED, FILLED, OR ADJUSTED AS NEEDED
IF:
(3) Remove inner wing nut and secondary element
(B).
(4) Install new secondary element and primary
element, making sure that the secondary
element is centered in canister.
(5) Install cover.
30
Semiannually
Change Pilot Control Oil Filter
WARNING: High-pressure release of oil from
pressurized system can cause serious burns or
penetrating injury. The hydraulic tank is
pressurized. Do not remove vent plug (A).
Release pressure by loosening vent plug.
(1) Loosen vent plug (A) to relieve air pressure.
A-23