TM 5-3805-281-10
Maintenance--Every 2000 Hours
12. Add oil until oil flows out of oil level check plug hole.
13. Wrap threads of check plug and fill plug with
sealing-type tape. Install plugs. Tighten plugs to 49
Nm (36 lb-ft).
Plug--Specification
Torque .......................................................................... 49 Nm (430 lb-in.)
14. Change oil of second propel gearbox.
CED,TX14740,6016
1902JUN982/2
CHANGE HYDRAULIC OIL
IMPORTANT: DO NOT run engine without oil in the
tank.
1. Park machine on level surface with upperstructure
rotated 90 for easier access.
2. Position machine with arm cylinder fully retracted and
bucket cylinder fully extended.
3. Lower bucket to the ground.
4. Turn auto-idle switch off.
IMPORTANT: Turbocharger may be damaged if
engine is not properly shut down.
5. Run engine with engine RPM dial at 1/3 position
without load for 2 minutes.
6. Move engine RPM dial to slow idle position.
7. Turn key switch to OFF to stop engine. Remove key
from switch.
8. Pull pilot control shut-off lever to locked position.
Continued on next page
TX,OUOE042,29
1908MAR991/7