MULTIMETER
SEVEN STEP ELECTRICAL TEST PROCEDURE - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  157    158    159    160    161  162  163    164    165    166    167  
img
.
TM 5-3805-281-24-1
System Information
SEVEN STEP ELECTRICAL TEST PROCEDURE
9015
05
16
A--Battery Ground
D--Fuse Or Circuit Breaker
G--Battery Side Of
I--Ground Side Of
B--Battery
E--Component Side Of
Component Terminal
Component Terminal
C--Battery Side Of Fuse Or
Fuse Or Circuit Breaker
H--Light (Component)
J--Component Ground
Circuit Breaker
F--Switch
Step 1--Switch ON
Check battery side of circuit breaker (C) for battery voltage
Battery voltage normal. Go to Step 2.
Low voltage, repair high resistance.
Open circuit from battery.
Step 2--Switch OFF
Check component side of circuit breaker for battery voltage
Battery voltage normal. Go to Step 4.
Low voltage, repair high resistance.
No voltage. Go to Step 3.
Continued on next page
TX,9015,MM2917B 1901MAY951/2