TM 5-3805-281-24-1
System Information
D--Circuit Name
H--Component
B--Power Wires
E--Section Number
Identification Code
C--Other Routing Location
F--Ground Wires
I--Component Schematic
Information
G--Component Name
Symbol
Other routing location information (C) is included for
The System Functional Schematic Diagram is made up
reference. In the example shown the Red/Wht wire
of sections which contain one or more Subsystem
also is connected to the Horn 10 Amp Fuse which is
Functional Schematics laid out side by side in a logical
located on Section 15 of the System Functional
sequence of related functions. Each Subsystem is a
Schematic; and the fuse identification number is F10.
major group of components like starting components or
charging components. Each Section of the System
The same names and identification codes are used on
Functional Schematic is assigned a number (E) and a
all machine drawings, the System Functional
name (D) that reflects that group of components. The
Schematic, the Harness Component Location Drawing
System Functional Schematic is formatted with power
and the Harness Connectors, Wires and Pin Location
supply wires (B) shown across the top of the drawing
drawings. Components and connectors can easily be
and ground wires (F) across the bottom. The
cross-referenced from one drawing to another. See
schematic contains no harness or connector
9015
Group 9015-10 for Functional Schematic and
information.
05
21
Component Location Legend.
Each electrical component is shown by a schematic
symbol (I), the component name (G), and a component
identification code (H). A continuity chart (A) is
included for the key switch.
CED,OUTX782,7 1919NOV982/2