SEVEN STEP ELECTRICAL TEST PROCEDURE
WIRING DIAGRAM, SCHEMATIC, AND COMPONENT LOCATION INFORMATION

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
TM 5-3805-281-24-1
System Information
Step 3--Switch OFF
Check component side of circuit breaker for continuity to ground
Continuity to ground. Repair grounded circuit at or before switch.
No continuity to ground, replace circuit breaker.
Step 4--Switch ON
Check component side of circuit breaker for battery voltage
Battery voltage normal. Go to Step 6.
Low voltage, repair high resistance.
No voltage. Go to Step 5.
Step 5
Disconnect wire at battery side of component (G). Switch ON. Check
Battery voltage, repair component.
wire at (G) for battery voltage
No voltage, repair grounded or open circuit at or after switch.
Step 6--Switch ON
Check lead to component at (G) for battery voltage
Battery voltage normal. Go to Step 7.
Low voltage, repair high resistance in circuit between fuse and
9015
component.
05
No voltage, repair high resistance or open circuit between fuse and
17
component.
Step 7--Switch ON
Check ground wire of component at (I) for voltage
No voltage, good continuity to ground.
Repair component.
Voltage, poor continuity to ground. Repair high resistance or open
ground circuit.
TX,9015,MM2917B 1901MAY952/2
4-17