Tests
k. Check the adjustments:
1. Actuate and hold right propel function over relief.
Engine pulldown must not go below 1950 rpm. If
it does, turn front pump load adjusting cartridge
(I) out until pulldown is 1950--1970 rpm. Record
rpm reading. Release propel function.
2. Actuate and hold left propel function over relief.
Engine pulldown must not go below 1950 rpm. If
it does, turn rear pump load adjusting cartridge
(I) out until pulldown is 1950--1970 rpm. Record
rpm reading. Release propel function.
3. The pulldown rpm reading for front and rear
pumps must be within 10 rpm of each other to
prevent machine from mistracking.
4. Check combined pump pulldown by operating
the arm in function through several cycles. The
combined pump pulldown must be less than 150
rpm. If more than 150 rpm, turn both load
adjusting cartridge out equal amounts so
combined pump pulldown is less than 150 rpm.
l. Connect the power boost pilot line at the right front
corner of control valve.
m. Make final pump regulator adjustments by
observing how straight the machine tracks under
9025
load.
25
120
G--13 mm Nut
H--Load Adjusting Screw (Inner Spring) (Engine
Pulldown at High Pressure)
I--Load Adjusting Cartridge (Outer Spring)
(Engine Pulldown at Medium Pressure)
J--30 mm Nut
Continued on next page