TM 5-3805-281-24-1
11. Install drum (A) on housing (B).
CAUTION: DO NOT heat oil over 182C (360F).
Oil fumes or oil can ignite above 193C (380F).
Use a thermometer. DO NOT allow a flame or
heating element to come in direct contact with
the oil. Heat the oil in a well-ventilated area.
Plan a safe handling procedure to avoid burns.
12. Heat bearing cone (C). Install cone tight against cup.
02
0250
Bearing Cone--Specification
29
Temperature ......................................................... 50--70C (122--158F)
A--Drum
B--Housing
C--Bearing Cone
Continued on next page
CED,OUOE023,159
1928MAY985/17
10-28