• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REPAIR INJECTION PUMP ANEROID--IF EQUIPPED
SERVICE INJECTION PUMP OVERFLOW VALVE

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  370    371    372    373    374  375  376    377    378    379    380  
img
.
TM 5-3805-281-24-2
Fuel System
DISASSEMBLE AND CLEAN HYDRAULIC
ANEROID ACTIVATOR PARTS--IF EQUIPPED
1. Remove gasket (G), piston (F) and piston spring (E).
2. Wash all parts in clean solvent and dry with
compressed air. Blow out all openings to make sure
they are open.
3. Check piston (F) and activator housing (H) for general
condition. Piston must move freely in its bore.
4. Inspect piston spring (E) and capillary valve spring (L).
Replace if weak or broken.
Inspecting Hydraulic Aneroid Activator
5. Inspect condition of restricter wire (K). Wire must not
A--Starting Fuel Control sHAFT
be bent or broken and must fit loosely in capillary valve
B--Return Spring
(J).
C--Washer
D--Retainer Ring
6. Check condition of return spring (B), washer (C) and
E--Piston Spring
retaining ring (D) on starting fuel control shaft (A).
F--Piston
G--Gasket
Replace spring if weak or broken. Be sure retaining
H--Activator Housing
ring is secure on shaft.
I--Mounting Screw (2 Used)
J--Capillary Valve Spring
K--Restricter Wire
L--Capillary Valve
M--Washers
N--Special Screw
RG,RG34710,1293
1923OCT971/1
ASSEMBLE AND INSTALL HYDRAULIC
ANEROID ACTIVATOR--IF EQUIPPED
NOTE: Refer to previous illustration.
To assemble and install activator, reverse disassembly
procedure using new gaskets.
RG,RG34710,1294
1923OCT971/1
11-374


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.