TM 5-3805-281-24-2
Fuel System
REMOVE AND INSTALL FUEL SHUTOFF SOLENOID--IF EQUIPPED
Fuel Shutoff Solenoid
A--Wiring Connector
D--Lever Cap Screw
G--Lock Washer and
I--Cap Screws
B--Fuel Shutoff Solenoid
E--Washer
Screws
J--Solenoid Mounting
C--Solenoid Shaft
F--Fuel Shutoff Lever
H--Hex Nuts
Bracket
IMPORTANT: Fuel shutoff solenoid linkage should
1. Disconnect electrical wiring connector (A) in
move freely back and forth. On "A"
solenoid lead.
pumps if linkage is binding, check
pump for proper alignment. (See
2. Remove cap screw (D), and detach solenoid shaft
INSTALL FUEL INJECTION PUMP,
(C) from fuel shutoff lever (F).
later in this group.)
3. Remove fuel shutoff solenoid (B) from solenoid
NOTE: Electric fuel shutoff solenoids are factory
mounting bracket (J) by removing hex nuts (H) and
adjusted to a specified length and should not
machine screws (G).
require additional adjustment. See CTM134 for
diagnosis of fuel shutoff solenoid.
4. If solenoid mounting bracket is to be removed,
remove cap screws (I) and washers (E) that fasten
the bracket to oil filter base.
6. To install fuel shutoff solenoid, reverse removal
procedure. Tighten cap screws (I) to 23 Nm
5. Inspect condition of solenoid and replace parts as
(17 lb-ft) and hex nuts (H) to 7 Nm (5 lb-ft).
necessary. (A repair kit is available from parts for
this solenoid assembly.)
RG,RG34710,1296
1923OCT971/1