TM 5-3805-281-24-2
Electrical System and Electrical Engine Controls
NOTE: If terminal cannot be removed, insert wire or nail
through extractor tool handle and push terminal
contact from connector.
IMPORTANT: Carefully spread contact lances to
assure good seating on connector
body.
NOTE: Connector bodies are "keyed" for correct contact.
Be sure contacts are correctly aligned.
Push contact into new connector body until fully seated.
Pushing Contact into Connector Body
Pull on wire slightly to insure contact is locked in position.
Transfer remaining wires to correct terminal in new
connector.
Close connector body.
RG,RG34710,1330
1923OCT974/4
INSTALL WEATHER PACKTM CONTACT
NOTE: Cable seals are color coded for three sizes of
wire:
Green - 18 to 20 gauge wire
Gray - 14 to 16 gauge wire
Blue - 10 to 12 gauge wire
Push correct size cable seal on wire.
IMPORTANT: The seal must fit snug over the cable
WEATHER PACKTM Contact
insulation, without a gap between the
cable seal and the insulation.
Strip insulation from wire to expose 6 mm (1/4 in.) and
align cable seal with edge of insulation.
WEATHER PACK is a trademark of Packard Electric.
Continued on next page
RG,RG34710,1331
1923OCT971/4