TM 5-3805-281-24-2
Removal and Installation
CAUTION: The approximate weight of splitter
housing with pumps is 195 kg (430 lb).
Splitter Housing with Pumps--Specification
Weight............................................................ 195 kg (430 lb) approximate
6. Remove cap screws (A). Remove splitter housing and
pumps.
7. Replace parts as necessary.
8. Install splitter housing and pumps.
A--Cap Screw (8 used)
9. Connect lines.
10. Tighten cap screws (G, O, and P).
Splitter Drive Cap Screw--Specification
Torque ............................................................................. 90 Nm (65 lb-ft)
12. Install muffler and bracket. (See procedure in Group
0530).
13. Do hydraulic pump start-up procedure. (See
procedure in Group 3360.)
08
0800
3
CED,OUOE024,231
1922MAY983/3
14-3