TM 5-3805-281-24-2
Group 0800
Removal and Installation
OTHER MATERIAL
Number
Name
Use
TY16285 (U.S.)
Cure Primer
Cleans and cures mating surfaces
TY9485 (Canadian)
prior to application of sealants.
7649 (LOCTITE)
TY9375 (U.S.)
Pipe Sealant
Apply to threads of splitter drive
TY9480 (Canadian)
elbow fitting and plug.
592 (LOCTITE)
T43514 (U.S.)
Plastic Gasket
Apply to mating surfaces of hydraulic
TY9475 (Canadian)
pumps and splitter housing.
277 (LOCTITE)
LOCTITE is a trademark of Loctite Corp.
CED,OUOE003,1129
1917SEP981/1
REMOVE AND INSTALL SPLITTER HOUSING
CAUTION: High pressure release of oil from
pressurized system can cause serious burns or
penetrating injury. The hydraulic tank is
pressurized. Do not remove vent plug. Release
pressure by loosening vent plug.
1. Loosen vent plug (A) to release air pressure in
hydraulic tank.
08
0800
2. Drain hydraulic tank. Approximate capacity is 159 L (42
1
gal).
A--Vent Plug
3. Remove muffler and bracket. (See procedure in Group
0530.)
Continued on next page
CED,OUOE024,231
1922MAY981/3