• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
TESTING ROTOR FOR SHORT CIRCUIT
REPLACING CARBON BRUSHES

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  516    517    518    519    520  521  522    523    524    525    526  
img
.
TM 5-3805-281-24-2
Robert Bosch Alternator Repair
30
TURNING DOWN SLIP RINGS
10
7
Turn down slip rings to a length of 20 mm (0.79 in.) only;
refer to (A).
Minimum diameter of slip rings 26.8 mm (1.055 in.).
RG,RG34710,2156 1915MAR971/1
TESTING STATOR COIL FOR SHORT
CIRCUIT
Test phase outlets with respect to each other as follows:
A and B; B and C; A and C.
With test lamp:
Test lamp must light up brightly
With ohmmeter:
Indications between 0.40 and 0.44 ohms.
If test fails, replace stator coil.
RG,RG34710,2157 1915MAR971/1
TESTING STATOR COIL FOR GROUNDS
Connect ohmmeter (or test lamp) to stator lead and stator
frame.
Repeat test for each stator lead.
If test shows continuity, replace stator.
RG,RG34710,2158 1915MAR971/1