TM 5-3805-281-24-2
Wiring Harness and Switches
REMOVE AND INSTALL OVERLOAD ALARM
PROXIMITY SWITCH
1. Disconnect connector (A).
2. Remove nuts (B) and proximity switch (D). Replace
parts as necessary.
3. Adjust gap (C) to 6.5--9.5 mm (1/4--3/8 in.).
A--Connector
B--Nut (2 used)
C--Gap 6.5--9.5 mm (1/4--3/8 in.)
D--Proximity Switch
CED,OUOE020,60 1920APR991/1
REMOVE AND INSTALL AUXILIARY
HYDRAULIC CONTROL SWITCH
16
1674
1. Remove connectors (C and D).
26
2. Remove cap screws (A).
3. Remove switch (B). Replace parts as necessary.
A--Cap Screw (2 used)
B--Switch
C--Connector
D--Connector
CED,OUOE020,61 1903MAY991/1