REMOVE CONNECTOR BODY FROM BLADE TERMINALS
REMOVE AND INSTALL OVERLOAD ALARM RELAY

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  542    543    544    545    546  547  548    549    550    551    552  
img
.
TM 5-3805-281-24-2
Wiring Harness and Switches
REMOVE AND INSTALL HYDRAULIC OIL
FILTER RESTRICTION SWITCH
1. Loosen vent plug (A) to relieve hydraulic oil tank
pressure.
2. Remove connector (G).
3. Disconnect hoses (B and C).
4. Remove elbow (D).
5. Remove cap screws (I), washers (H) and nuts (F).
6. Remove switch (E). Replace parts as necessary.
A--Vent Plug
B--Hose
C--Hose
D--Elbow
E--Switch
F--Nut (2 used)
G--Connector
H--Washer (2 used)
I--Cap Screw (2 used)
16