TM 5-3805-281-24-2
Wiring Harness and Switches
INSTALL DEUTSCHTM CONTACT
1. Strip 6 mm (1/4 in.) insulation from wire.
2. Adjust selector (A) on JDG360 Crimper1 for correct
wire size.
3. Loosen lock nut (B) and turn adjusting screw (C) in
until it stops.
A--Crimper Selector
B--Lock Nut
C--Adjusting Screw
DEUTSCH is a trademark of the Deutsch Co.
1
Included in JDG359 Deutsch Electrical Repair Kit.
ECONN,W 1904JUN901/4
IMPORTANT: Select proper size contact "sleeve" or
"pin" to fit connector body.
4. Insert contact (A) and turn adjusting screw (D) until
contact is flush with cover (B).
5. Tighten lock nut (C).
A--Contact
B--Cover
C--Lock Nut
D--Adjusting Screw
16
1674
18
ECONN,W 1904JUN902/4
IMPORTANT: Contact must remain centered between
indentors while crimping.
6. Insert wire in contact and crimp until handle touches
stop.
7. Release handle and remove contact.
Continued on next page
ECONN,W 1904JUN903/4