REMOVE AND INSTALL OVERLOAD ALARM RELAY
REMOVE AND INSTALL OVERLOAD ALARM PROXIMITY SWITCH

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  544    545    546    547    548  549  550    551    552    553    554  
img
.
TM 5-3805-281-24-2
Wiring Harness and Switches
REMOVE AND INSTALL OVERLOAD ALARM
PRESSURE SWITCH
1. Loosen vent plug (A) on hydraulic oil tank to relieve
hydraulic oil tank pressure.
2. Disconnect connector (D).
3. Disconnect hose (E).
4. Remove cap screws (F), mount (C) and pressure
switch (B). Replace parts as necessary.
A--Vent Plug
B--Pressure Switch
C--Mount
D--Connector
E--Hose
F--Cap Screw (2 used)
16
1674
25
CED,OUOE020,59 1920APR991/1