TM 5-3805-281-24-2
00--Bracket
07--Washer (4 used)
17--Cap Screw (2 used)
27--Compressor
01--Cap Screw
08--Pulley
18--Wire Harness
02--Spring Washer
10--Bracket (2 used)
19--Clip (7 used)
29--Receiver Dryer
03--Cap Screw (2 used)
11--Cap Screw (4 used)
20--Cap Screw (4 used)
04--Spring Washer (2
12--Cap Screw (4 used)
21--Clip (2 used)
used)
13--Cap Screw (2 used)
22--Clip (3 used)
05--Cap Screw (4 used)
14--Hose
23--Spacer
06--Spring Washer (4
15--Hose
25--Compressor V-Belt
used)
16--Cap Screw (2 used)
26--Washer
5. Evacuate and charge the system. (Seeprocedures
1. Recover the refrigerant from the system. (See
in this group.)
procedure in this group.)
6. Install air conditioning compressor V-belt (25). (See
2. Remove air conditioning compressor V-belt (25).
procedure in Group 0510.)
(See procedure in group 0510.)
7. Adjust air conditioning compressor V-belt tension.
3. Remove and install compressor (27). Install caps
(See procedure in Group 0510.)
and plugs to close all open lines.
4. Repair or replace compressor as necessary.
CED,OUOE027,272
1929MAY982/2
DISASSEMBLE AND INSPECT AIR
CONDITIONING COMPRESSOR
1. Mount holding fixture in a bench vise and support
compressor on holding fixture.
NOTE: Mounting fixture can be made with two pieces of
flat stock and two lengths of threaded rod.
Weld one piece of stack perpendicular to other,
drill two holes and install threaded rod as shown.
Compressor can also be mounted in pivoting
D01006AA Bench Mounted Holding Fixture or
similar holding device.
2. Put compressor in a bench holding fixture.
18
1830
19
Continued on next page
T52,1830,K184
1923AUG971/26