TM 5-3805-281-24-2
Hydraulic System
5. Install element (D) making sure it is pushed down on
its seat at bottom of case.
33
3360
6. Install filter bypass valve (E), spring (C), O-ring (F),
133
cover (A) and cap screws (B).
Tighten cap screws.
Return Filter Cover-to-Hydraulic Oil Tank Cap Screw--Specification
Torque ............................................................................. 49 Nm (36 lb-ft)
7. Add hydraulic oil as necessary. (See Hydraulic Oil in
Group 0004.)
IMPORTANT: Hydraulic pump will be damaged if not
filled with oil before starting. Procedure
must be performed to fill pump housing
whenever oil has been drained from the
pump or hydraulic oil tank.
8. If hydraulic oil tank was drained, do Hydraulic Pump
Start-Up Procedure. (See procedure in this group.)
A--Cover
B--Cap Screw
C--Spring
D--Element
E--Filter Bypass Valve
F--O-Ring
CED,OUOE026,7
1918JUN983/3
19-161