ASSEMBLE ACCUMULATOR
NITROGEN RECHARGE - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  913    914    915    916    917  918  919    920    921    922    923  
img
TM 5-3805-281-24-2
Hydraulic Impact Breaker
33
NITROGEN RECHARGE
60
1. Carefully insert pressure reducer/regulator assembly
into nitrogen tank, following safety instructions.
Nitrogen bottle must not have a level below 45 bars
(652.5 psi).
CED,OUOE039,4
1920MAR993/7
2. Attach rubber hose to pressure reducer/regulator and
nitrogen tank valve.
3. Attach inflating body so hexagonal pin fits inside
inflating screw (A). Check O-ring on sealing face.
Continued on next page
CED,OUOE039,4
1920MAR994/7