(11) Turn filter (B) counterclockwise to remove.
Clean mounting surface on base.
(12) Apply a thin film of oil to rubber gasket of new
filter.
(13) Install new filter. Turn filter clockwise by hand
until gasket touches mounting surface.
(14) Tighten filter 1/2--3/4 turns more.
(15) Install drain plug or close drain valve.
(16) Remove fill cap (C).
(17) Fill engine with oil (see Fuels and Lubricants,
Chapter 11).
SPECIFICATION
Oil Capacity With Filter Change
19 L (20 qt)
(18) Install fill cap.
(19) Start engine.
NOTE: Engine oil pressure indicator on
monitor must go out within 15--20 seconds. If
not, stop the engine immediately and find the
cause.
(20) Stop engine. Check oil level.
(21) Check for any leakage at filter. If so, tighten
filter just enough to stop leakage and repeat
steps 19 through 21.
(22) Install cover from under the engine.
A-8