TM 5-3805-294-10
OPERATOR MAINTENANCE
HYDRAULIC FUNCTIONS ARE SLOW OR HAVE LITTLE OR NO POWER
INITIAL SETUP:
Equipment Condition
References
Machine safely parked and shut down.
TROUBLESHOOTING PROCEDURE
Table 1. Hydraulic Functions Are Slow or Have Little or No Power.
Test or Inspection
Corrective Action
Malfunction
Check hydraulic oil level.
1.
If hydraulic oil level is correct,
1.
Hydraulic Oil Level
proceed to Malfunction 2.
Low.
2.
If hydraulic oil level is not
correct, fill oil to proper level.
Perform operating in cold
1.
If hydraulic functions operate
2.
Hydraulic Oil Cold.
weather below 5F (-15C)
properly, malfunction
corrected.
weather 32 to 5F (0 to
2.
If hydraulic functions do not
operate properly, proceed to
Malfunction 3.
Visually inspect hydraulic
1.
If damaged or missing
3.
Hydraulic Reservoir
reservoir fill cap for damage or
hardware, notify Field
Fill Cap is Damaged
Maintenance.
or Missing
Hardware.
2.
if not damaged or missing
hardware, notify Field
Maintenance.
END OF WORK PACKAGE
0059-1/2 blank