POWER DIG DOES NOT WORK
HYDRAULIC OIL FOAMS

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  253    254    255    256    257  258  259    260    261    262    263  
img
. . . . . . .
TM 5-3805-294-10
0061
OPERATOR MAINTENANCE
HYDRAULIC OIL OVERHEATS
INITIAL SETUP:
Equipment Condition
References
Machine safely parked and shut down.
WP 0077
(WP 0009)
WP 0088
TROUBLESHOOTING PROCEDURE
Table 1. Hydraulic Oil Overheats.
Malfunction
Test or Inspection
Corrective Action
Visually inspect cooling
1.
If damaged, notify Field
1.
Cooling Package
package for damage, foreign
Maintenance.
Has Damage,
Foreign Objects/
objects/debris. (WP 0077)
2.
If not damaged but has foreign
Debris.
objects/debris, remove foreign
objects/debris.
3.
If not damaged and does not
have foreign objects/debris,
proceed to Malfunction 2.
Check hydraulic oil level.
1.
If hydraulic oil level is correct,
2.
Hydraulic Oil Level
notify Field Maintenance.
Low.
(WP 0077)
2.
If hydraulic oil level is not
correct, fill oil to proper level.
(WP 0088)
END OF WORK PACKAGE