COMPACTOR DOES NOT OPERATE
BREAKER OPERATES SLOWLY

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  263    264    265    266    267  268  269    270    271    272    273  
img
. . . . . . . . . .
TM 5-3805-294-10
0070
OPERATOR MAINTENANCE
BREAKER DOES NOT OPERATE
INITIAL SETUP:
Equipment Condition
References
Machine safely parked and shut down.
WP 0020
(WP 0009)
WP 0077
TROUBLESHOOTING PROCEDURE
Table 1. Breaker Does Not Operate.
Malfunction
Test or Inspection
Corrective Action
Visually inspect hydraulic
1.
If quick disconnect is fully
1.
Hydraulic Supply
supply quick disconnect.
seated, proceed to Malfunction
Quick Disconnect
2.
Not Fully Seated.
(WP 0077)
2.
If quick disconnect is not fully
seated, reconnect quick
disconnect properly.
(WP 0020)
3.
If quick disconnect is
damaged, notify Field
Maintenance.
Visually inspect hydraulic
1.
If quick disconnect is fully
2.
Hydraulic Return
return quick disconnect.
seated, proceed to Malfunction
Quick Disconnect
3.
Not Fully Seated.
(WP 0077)
2.
If quick disconnect is not fully
seated, reconnect quick
disconnect properly.
(WP 0020)
3.
If quick disconnect is
damaged, notify Field
Maintenance.
Visually inspect breaker for
1.
If breaker does have jammed
3.
Breaker Has
debris, remove jammed
Jammed Debris.
jammed debris. (WP 0077)
debris. (WP 0077)
2.
If breaker does not have
jammed debris, notify Field
Maintenance.
END OF WORK PACKAGE
0070-1/2 blank