TM 5-3805-294-10
OPERATOR MAINTENANCE
CRUSH-ALL DOES NOT OPERATE
INITIAL SETUP:
Equipment Condition
References
Machine safely parked and shut down.
TROUBLESHOOTING PROCEDURE
Table 1. Crush-All Does Not Operate.
Test or Inspection
Corrective Action
Malfunction
1.
Remove F6 OPT.2 (ALT) 10A
1.
12-Volt Power
Outlet Fuse Blown.
2.
Visually inspect F6 OPT.2
1.
If fuse blown, replace F6 OPT.
(ALT) 10A fuse for blown fuse.
2.
If fuse not blown, proceed to
Malfunction 2.
Visually inspect hydraulic
1.
If quick disconnect is fully
2.
Hydraulic Supply
supply quick disconnect.
seated, proceed to Malfunction
Quick Disconnect
3.
Not Fully Seated.
2.
If quick disconnect is not fully
seated, reconnect quick
disconnect properly.
3.
If quick disconnect is
damaged, notify Field
Maintenance.
Visually inspect hydraulic
1.
If quick disconnect is fully
3.
Hydraulic Return
return quick disconnect.
seated, proceed to Malfunction
Quick Disconnect
4.
Not Fully Seated.
2.
If quick disconnect is not fully
seated, reconnect quick
disconnect properly.
3.
If quick disconnect is
damaged, notify Field
Maintenance.
0072-1