Figure 3. Hydraulic Reservoir Cover Installation.
Figure 2. Inspect Seal.

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  350    351    352    353    354  355  356    357    358    359    360  
img
. . . . . .
TM 5-3805-294-10
0089
OPERATOR MAINTENANCE
FRESH AIR FILTER SERVICE
INITIAL SETUP:
Materials/Parts
Equipment Condition
Machine safely parked and shut down.
Rag, Wiping (WP 0097, Table 1, Item 15)
(WP 0009)
Personnel Required
Horizontal Construction Engineer 12N (1)
Time to Complete
0.2 Hour(s)
References
TM 5-3805-295-13&P (WP 0094)
DA FORM 5988-E or DA FORM 2404 (WP 0094)
REMOVAL
NOTE
After the fresh air filter has been serviced three times, it must be replaced by Field
Maintenance.
1.
Move two tabs (Figure 1, Item 1) inward and remove filter (Figure 1, Item 2) from housing (Figure 1, Item 3).
1
1
3
2
HYEX00168
Figure 1. Filter Removal.
2.
Inspect seal (Figure 2, Item 4) on filter (Figure 2, Item 2).
0089-1