Table 1. DTC 174.03 - Fuel Temperature Signal Out of Range High - Continued.
Table 1. DTC 174.03 - Fuel Temperature Signal Out of Range High - Continued.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  291    292    293    294    295  296  297    298    299    300    301  
img
TM 5-3805-294-23-1
0043
Table 1. DTC 174.03 - Fuel Temperature Signal Out of Range High - Continued.
Test or Inspection
Corrective Action
Malfunction
5.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0363)
6.
Under Connected Data Points,
select ECU - (shown with
engine serial number).
(Volume 3, WP 0363)
7.
Under ECU - (shown with
engine serial number), select
ECU - Data List - All. (Volume
3, WP 0363)
8.
Under ECU - Data List - All,
select Fuel Temperature Input
Voltage. (Volume 3,
WP 0363)
9.
Monitor the Fuel Temperature
Input Voltage while gently
wiggling the engine wiring
harness between connectors
J03 and T05. Note any
fluctuations in the voltage. The
input voltage will increase to
approximately 5V when the
sensor circuit is open.
10.
When finished monitoring,
select Readings and select
Disconnect From Model(s).
(Volume 3, WP 0363)
11.
Select Yes to terminate your
readings connection. (Volume
3, WP 0363)
12.
Turn the key switch to the OFF
1.
If voltage fluctuated, replace
position (TM 5-3805-294-10).
engine wiring harness.
(Volume 5, WP 0794)
(Volume 4, WP 0510) Restore
machine to original condition
and perform Harness
Diagnostic Mode Test.
(Volume 3, WP 0345)
2.
If voltage did not fluctuate,
proceed to Malfunction 14.
0043-7