• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. DTC 655.13 - Injector #5 Calibration Fault - Continued.
Table 1. DTC 655.13 - Injector #5 Calibration Fault - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  594    595    596    597    598  599  600    601    602    603    604  
img
TM 5-3805-294-23-1
0089
Table 1. DTC 655.13 - Injector #5 Calibration Fault - Continued.
Test or Inspection
Corrective Action
Malfunction
18.
Select Reading and select
Disconnect From Model(s).
(Volume 3, WP 0340)
19.
Select Yes to terminate your
readings connection. (Volume
3, WP 0340)
20.
Turn key switch to OFF
position for a minimum of 90
seconds to complete the
calibration. (TM
5-3805-294-10). (Volume 5,
WP 0794)
21.
Clear and refresh DTCs. Note
1.
If DTC 655.13 is still an active
if DTC 655.13 is still an active
DTC, it is possible that another
fault exists or that another
DTC. (Volume 3, WP 0362)
troubleshooting procedure
applies. If this was the first time
through this procedure, restart
procedure at Malfunction 1.
2.
If DTC 655.13 is not an active
DTC, problem corrected.
1.
Turn key switch to ON position,
3.
Re-enter Injector
but DO NOT START ENGINE
Data.
(TM 5-3805-294-10). (Volume
5, WP 0794).
2.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0340)
3.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0340)
4.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0340)
5.
Select Tests and Calibrations
tab in Service ADVISOR and
select 240DLCR - Excavator -
None. (Volume 3, WP 0340)
0089-5


Privacy Statement
Press Release
Contact