Table 1. DTC 655.13 - Injector #5 Calibration Fault - Continued
Table 1. DTC 655.13 - Injector #5 Calibration Fault - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  596    597    598    599    600  601  602    603    604    605    606  
img
TM 5-3805-294-23-1
0089
Table 1. DTC 655.13 - Injector #5 Calibration Fault - Continued.
Test or Inspection
Corrective Action
Malfunction
15.
After Calibration Complete
appears, select OK. (Volume
3, WP 0340)
16.
Select Exit and then select
Yes. (Volume 3, WP 0340)
17.
Select Reading and select
Disconnect From Model(s).
(Volume 3, WP 0340)
18.
Select Yes to terminate your
readings connection. (Volume
3, WP 0340)
19.
Turn key switch to OFF
position for a minimum of 90
seconds to complete the
calibration. (TM
5-3805-294-10). (Volume 5,
WP 0794)
20.
Clear and refresh DTCs. Note
1.
If DTC 655.13 is still an active
if DTC 655.13 is still an active
DTC, proceed to Malfunction
4.
DTC. (Volume 3, WP 0362)
2.
If DTC 655.13 is not an active
DTC, problem corrected.
1.
Replace ECU. (Volume 4,
4.
ECU Faulty.
WP 0508)
2.
Turn key switch to ON position,
but DO NOT START ENGINE
(TM 5-3805-294-10). (Volume
5, WP 0794).
3.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0340)
4.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0340)
5.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0340)