TM 5-3805-294-23-1
FIELD MAINTENANCE
DTC 1172.03 - COMPRESSOR INLET TEMPERATURE SIGNAL OUT OF RANGE HIGH
INITIAL SETUP:
References (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
Volume 3, WP 0345
(Volume 5, WP 0796, Table 2, Item 119)
Volume 3, WP 0362
Accessory Kit, MSD Electronic Equipment
Volume 3, WP 0363
(Volume 5, WP 0796, Table 2, Item 2)
Volume 3, WP 0369
Volume 3, WP 0486
(Volume 5, WP 0796, Table 2, Item 77)
Volume 4, WP 0509
Probe Set, Standard
Volume 4, WP 0510
(Volume 5, WP 0796, Table 2, Item 91)
Volume 4, WP 0511
Test Set, MSD Electronic Systems
Volume 5, WP 0800
(Volume 5, WP 0796, Table 2, Item 116)
Equipment Condition
Materials/Parts
Machine safely parked and shut down (TM
Wire, Jumper
5-3805-294-10). (Volume 5, WP 0794)
(Volume 5, WP 0792)
Test Equipment Setup for MSD and Service
ADVISOR. (Volume 3, WP 0375)
Personnel Required
Construction Equipment Repairer 91L (2)
References
TM 5-3805-294-10 (Volume 5, WP 0794)
Troubleshooting Sequence
1172.03
When DTC is Displayed
Whenever the ignition is ON and the error is active.
Related Information
The compressor inlet temperature input voltage increases above the sensor's high voltage specification. This
corresponds to a temperature that is lower than what is physically possible for compressor inlet temperature.
Alarm Level
Warning.
The ECU uses a default compressor inlet temperature of 86F (30C).
The ECU will try to maintain the engine operating envelope.
0098-1