Table 1. Engine Emits Excessive White Exhaust Smoke - Continued
ENGINE IDLES POORLY

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  795    796    797    798    799  800  801    802    803    804    805  
img
TM 5-3805-294-23-1
0118
Table 1. Engine Emits Excessive White Exhaust Smoke - Continued.
Test or Inspection
Corrective Action
Malfunction
Perform Head Gasket Failure
1.
If problems found, replace
11.
Head Gasket Faulty.
cylinder head and/or cylinder
Check. (Volume 3, WP 0346)
head gasket. (Volume 3,
Note any defects.
WP 0407) Restore machine to
original condition.
2.
If no problems found, replace
engine. (Volume 3, WP 0410)
Restore machine to original
condition.
END OF WORK PACKAGE