Table 1. Low-Pressure Fuel Supply System Test - Continued
Table 1. Low-Pressure Fuel Supply System Test - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  912    913    914    915    916  917  918    919    920    921    922  
img
TM 5-3805-294-23-1
0131
Table 1. Low-Pressure Fuel Supply System Test - Continued.
Test or Inspection
Corrective Action
Malfunction
1.
Reconnect connector H01.
20.
Open Circuit
Between Connector
(Volume 5, WP 0800, Figure
C31 Socket A and
40)
F16 POWER ON 5A
Fuse Socket 2.
2.
Using a jumper wire, measure
1.
If continuity is present,
resistance (Volume 3,
proceed to Malfunction 24.
WP 0369) between connector
2.
If continuity is not present,
C31 socket A (Volume 5,
proceed to Malfunction 21.
WP 0800, Figure 33) and F16
POWER ON 5A Fuse Socket
2. (Volume 5, WP 0800,
Figure 161) Note reading.
1.
Disconnect connector H01.
21.
Open Circuit
Between Connector
(Volume 5, WP 0800, Figure
H01 Pin 1 and F16
40)
POWER ON 5A
Fuse Socket 2.
2.
Using jumper wire, measure
1.
If continuity is present, replace
resistance (Volume 3,
machine wiring harness.
WP 0369) between connector
(Volume 4, WP 0516) Restore
H01 pin 1 (Volume 5,
machine to original condition.
WP 0800, Figure 33) and F16
2.
If continuity is not present,
POWER ON 5A Fuse Socket
proceed to Malfunction 22.
2. (Volume 5, WP 0800,
Figure 161) Note reading.
1.
Disconnect the following
22.
Connector X3 Has
connectors:
Damage or Loose
Pins/Sockets.
a. Connector X3. (Volume
5, WP 0800, Figure 84)
b. Connector X4. (Volume
5, WP 0800, Figure 85)
c. Connector X41.
(Volume 5, WP 0800,
Figure 102)
d. Connector X42.
(Volume 5, WP 0800,
Figure 103)
2.
Unmount and reposition the
cab wiring harness connectors
for service. (Volume 3,
WP 0312)
0131-8