Table 1. Low-Pressure Fuel Supply System Test - Continued
CHAPTER 6. FIELD MONITOR CONTROLLER TROUBLESHOOTING PROCEDURES FOR HYDRAULIC EXCAVATOR TYPE 1 (HYEX) NSN 3805-01-573-0677

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  920    921    922    923    924  925  926    927    928    929    930  
img
TM 5-3805-294-23-1
0131
Table 1. Low-Pressure Fuel Supply System Test - Continued.
Test or Inspection
Corrective Action
Malfunction
14.
Shut down engine and turn the
1.
If pressure reading was within
key switch to the OFF position
4 psi (30 kPa) of gauge, low-
(TM 5-3805-294-10). (Volume
pressure fuel supply system
operating correctly. Return to
5, WP 0794)
original troubleshooting
procedure.
2.
If fuel pressure is not 4.4 psi
(30 kPa) or above, it is possible
that another fault exists or that
another troubleshooting
procedure applies. If this was
the first time through this
procedure, restart procedure
at Malfunction 1.
END OF WORK PACKAGE