TM 5-3805-294-23-4
0493
SERVICE - Continued
2.
Clean four battery terminals (Figure 3, Item 8), (Figure 3, Item 12), (Figure 3, Item 16), and (Figure 3, Item 21)
with technical sodium bicarbonate and stiff bristle brush as required.
3.
Apply sealing compound around battery terminal base only.
4.
Remove 12 caps (Figure 4, Item 22).
22
23
HYEX00507
Figure 4. Battery Electrolyte Level Range.
5.
Check electrolyte level and fill each cell, to within specified range (Figure 4, Item 23) of 0.25 in. (6 mm) with
distilled water.
6.
Install 12 caps (Figure 4, Item 22).
END OF TASK
INSTALLATION
WARNING
LEAD-ACID BATTERIES
Avoid battery electrolyte contact with skin, eyes, and clothing. If battery electrolyte spills, take
the following immediate action to stop burning effects:
External - If battery electrolyte contacts skin, immediately flush affected area with cold running
water. Failure to comply may result in injury or death to personnel.
Eyes - If battery electrolyte contacts eyes, immediately flush eyes with cold water for 15
minutes and seek immediate medical attention. IMPORTANT - If only one eye is affected,