TORQUE TABLE FOR D66 DRIVE HEAD UNIT WITH DIFFERENTIAL LOCK
(AS FITTED TO STEER DRIVE AXLE)
Item
Description
No
1
Coupling flange nut
800 - 900 lbs. ft
(1085 -1220Nm)
5
Pinion housing nut
47 - 53 lbs ft
(64 - 72 Nm)
10
Axle casing nut
99 - 108 lbs ft
(134 - 148 Nm)
13
Diff. strap stud
88 - 98 lbs ft
(119 - 133 Nm)
16
Diff. cage nut
166 - 184 lbs ft
(225 - 250 Nm)
21
Diff. strap nut
128 - 142 lbs ft
174 - 193 Nm)
SEE FOLLOWING PAGE FOR STUD TIGHTENING PROCEDURE
Manual No. 1785 Issue A
Page No.C26
Spicer Speciality Axle Division
J-90