Section 1 - Cylinder Block - Group 1
Cylinder Block - De-Glazing (1-05)
B Series Shop Manual
Page 1-19
NOTE: Vertical strokes must be smooth continuous passes
along the full length of the bore.
Inspect the bore after 10 strokes.
Caution: Be extremely careful not to hone the bore out
of specification.
A sizing hone can be used to remove minor grooves or to
correct minor out of taper.
Taper:
0.076 mm [0.003 in]
Operate the sizing hone similarly to the Flexi-Hone.
Inspect the bore after 10 strokes.
Immediately clean the cylinder bores with a strong solu-
tion of laundry detergent and hot water.
After rinsing, use compressed air to dry the block.