KSB Electrical Solenoid Style - Inspection - Continued
Injection Pump Repairs - Bosch VE

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  306    307    308    309    310  311  312    313    314    315    316  
img
TM 5-2420-230-24-2
KSB Electrical Solenoid Style - Inspection
Section 5 - Fuel System - Group 05
Page 5-14
B Series Shop Manual
Use a very small screwdriver to be sure the check ball is
not sticking.
NOTE: A sticking or malfunctioning pressure relief valve will
result in either white smoke or a ruptured fuel pump housing.
Replace the pressure relief valve assembly if necessary.
17 mm
Install the original pressure relief valve or a replacement
into the KSB housing.
Torque Value: 13 Nm
[10 ft-lb]
KSB Electrical Solenoid Style Wiring Harness
- Inspection
The wiring harness used on the electric solenoid style
KSB can be inspected using a volt-ohm meter.
NOTE: Pin `B' of the metro-pack connector is blank on the
electric solenoid style KSB wiring harness.
The electric solenoid style KSB wiring harness contains
a 3 ohm resistor in the wire leading from Port `C' of the
metro-pack connector to the KSB electrical solenoid con-
nector.
The 3 ohm resistor is mounted to a bracket which is used
as a `heat sink' to absorb heat that is generated by the
resistor.
CPI 1351 incorporates the resistor in the wiring harness.
CPL 1579 does not require a resistor.