TM 5-2420-230-24-2
Section 5 - Fuel System - Group 05
Injection Pump Repairs - Bosch VE (5-01)
B Series Shop Manual
Page 5-15
Use a volt/ohm meter to perform a continuity check be-
tween Port `C' of the metro-pack connector and the KSB
Repair the wire if there is an open circuit.
(Spec = Less than 10 ohms).
Use a volt/ohm meter to perform a continuity check be-
tween Port `A' of the metro-pack connector and the fuel
Repair the wire if there is an open circuit.
(Spec = Less than 10 ohms).
Injection Pump Repairs - Bosch VE
(5-01)
Shaft Seal - Replacement (5-02)
Seal Puller Part No. 3376933
Remove the seal.
Inspect the seal seating area for nicks and burrs. Minor
clean-up (deburring) is allowed providing the area is thor-
oughly flushed with solvent and dried with compressed
air.
L-313