Shutdown Solenoid - Replacement (5-04)
Overflow Adapter/Sealing Ring - Replacement (5-06)

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  310    311    312    313    314  315  316    317    318    319    320  
img
TM 5-2420-230-24-2
Injection Pump Repairs - Bosch VE (5-01)
Section 5 - Fuel System - Group 05
Page 5-18
B Series Shop Manual
24 mm
Install the new fuel solenoid, plunger and spring into the
distributor head.
Tighten the solenoid securely.
Torque Value: 43 Nm
[32 ft-lb]
Shutdown Lever/Spring - Replacement (5-05)
Caution: Mark the shutdown lever so it can be installed
in the same position. Failure to do so will result in in-
correct installation.
Disconnect the return spring.
10 mm
Remove the lever and spring.