Delivery Valves (Back Leakage Valves on Lucas CAV Pumps)
Fuel Lift Pump (005-045)

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  918    919    920    921    922  923  924    925    926    927    928  
img
TM 5-2420-230-24-2
Fuel Shutoff Valve (005-043)
B3.9 and B5.9 Series Engines
Page 5-74
Section 5 - Fuel System - Group 05
Install (005-043-026)
Bosch VE
``Package'' the solenoid, o-ring, spring, and plunger.
24 mm
Tighten the solenoid securely.
Connect the electric wire.
Torque Value: 43 Nm
[32 ft-lb]
5/16 Inch
Stanadyne DB4
Install new insulating tubes onto the terminals on the ter-
minal studs of the new solenoid.
Install the valve into the cover.
Torque Value: 14 Nm
[124 in-lb]
5/16 Inch
Install the cover and gasket onto the fuel injection pump.
With the tool installed as shown, place the cover in position
on the pump housing. Twist the tool to release it, and slide
it out from between the cover and the housing.
NOTE: Extreme care must be taken in assembling the
cover to a fuel injection pump to make sure the shutoff arm
is in proper contact with the linkage hook tab.
L-934