• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Fuel Lift Pump (005-045) - Continued
Fuel Transfer Pump Flow Volume

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  924    925    926    927    928  929  930    931    932    933    934  
img
TM 5-2420-230-24-2
Fuel Lift Pump (005-045)
B3.9 and B5.9 Series Engines
Page 5-80
Section 5 - Fuel System - Group 05
Test 1: Output Pressure Test (Piston Style)
Operate the engine, and measure the output pressure of
the fuel transfer pump using an in-line pressure gauge at
the inlet to the injection pump.
Minimum pressure at rated speed is 172 kPa [25 psi].
Test 2: Flow Volume Test (Piston Style)
CAUTION
To prevent the engine from starting, disconnect the fuel
shutdown wiring. Residual fuel in the injection pump
can cause the engine to start.
CAUTION
Do not crank the starter for more than 30 seconds at a
time. Doing so can result in starter damage. Also, high
voltage during cranking can damage the shutdown
solenoid.
Tachometer, Part No. 3377462
Disconnect the fuel shutdown solenoid wire.
Measure the engine cranking speed with a handheld ta-
chometer (Cummins Part No. 3377462).
CAUTION
Leave the shutdown solenoid disconnected for the fol-
lowing check:
Disconnect the output pressure line from the transfer pump,
and run it into a container.
Crank the engine for 30 seconds, and measure the fuel
transfer pump flow volume.
Refer to following chart(s).
L-940


Privacy Statement